Syrotech-GOXQ28-100GBASE-ER4-transceiver module-QSFP28-MSA-LAN WDM-hot pluggable-40Km
- Description
- Shipping & Returns
- Reviews
QSFP28 100GBASE-ER4 is Syrotech's 100Gb/s optical communication module compliant with Ethernet 100GBASE-ER4 Lite standard. Input channels of 25Gb/s electrical data are converted into LAN WDM optical signals and multiplexed into a single channel for 100Gb/s transmission.
On the receiver side, the module converts 4 LAN WDM optical signals into 4 electrical output channels from a 100Gb/s optical input. As defined in IEEE 802.3ba, the wavelengths of the four LAN WDM channels are 1295.56, 1300.05, 1304.58, and 1309.14 nm.APD receivers with high sensitivity provide superior performance for 100Gigabit Ethernet applications up to 30km with no FEC and 40km with FEC.
APPLICATION
➛Ethernet links with 100GBASE-ER4
➛Interconnects for Infiniband QDR and DDR
➛Telecom 100G connections for clients
KEY FEATURES:
➛ Form factor QSFP28 MSA hot-pluggable
➛ Provides aggregate bit rates of 103.1 GB/s
➛ Complies with Ethernet 100GBASE-ER4Lite
➛ QSFP28-ER4-100G is RoHS-6 compliant
➛ EML TOSA cooled 4x25Gb/s LAN WDM (1295.56, 1300.05, 1304.58, 1309.14nm) transmitter
➛ 4x25Gb/s APD ROSA receiver
➛ Electrical interface for 4x25G (OIF CEI28G-VSR)
➛ Temperature range for commercial use: 0°C to 70°C
➛ Power supply with 3.3V
➛ G.652 SMF without FEC reaches up to 30km
➛ G.652 SMF with FEC has a reach of up to 40km
PRODUCT SPECS:
Parameter |
Min |
Typ. |
Max |
Data Rate, all Lanes combined |
103.1 Gbps |
||
Data Rate, each Lane |
25.78125 |
Gb/s |
|
Link Distance with G.652 (without FEC) |
30 Km |
||
Link Distance with G.652 (with FEC) |
40 Km |
In the transceiver module, four channels of 25Gb/s electrical data are received, which are reshaped and reduced in jitter by a four-channel Clock and Data Recovery (CDR) IC. Each of the 4 cooled EML lasers in the Transmitter Optical Sub-Assembly (TOSA) is then driven by an EML laser driver IC that converts the 4 electrical channels into an optical signal. IEEE 802.3ba 100GBASE-ER4 specifies a specific wavelength for each laser when it launches an optical signal.
The optical output power of each channel is maintained constant by an automatic power control (APC) circuit. A 4-to-1 optical WDM MUX will split these four optical signals into one fiber. By using the TX_DIS hardware signal or the 2-wire serial interface, the transmitter output can be turned off.
ELECTRICAL SPECS:
Parameter |
Minimum |
Typical |
Maximum |
|
Power Consumption |
4.5 W |
|||
Supply Current |
1.36 A |
|||
Transmitter |
||||
Overload Differential Voltage pk-pk |
900 |
mV |
||
Common Mode Voltage (Vcm) |
-350 |
2850 mV |
||
Differential Termination Resistance Mismatch |
10 % @ 1 Mhz |
|||
Differential Return Loss (SDD11) |
See CEI- 28GVSREquation 13-19 dB |
|||
(SDC11, SCD11) Conversion between Common Mode and Differential Mode |
See CEI- 28GVSREquation 13-20 dB |
|||
Input Stress Test |
See CEI- 28GVSRSection13. 3.11.2.1 |
|||
Receiver |
||||
Differential Voltage, pk-pk |
900 V |
|||
Common Mode |
-350 |
2850 mV |
||
Differential Termination Resistance Mismatch |
10 % @ 1 Mhz |
|||
Differential Return Loss (SDD22) |
See CEI- 28GVSREquation1 3-19 dB |
|||
Conversion from Common Mode to Differential Mode (SDC22, SCD22) |
See CEI- 28GVSREquation 13-21 dB |
|||
Communal Mode Return Loss (SCC22) |
-2 dB |
|||
Transition Time, 20 to 80% |
9.5 |
ps |
||
Vertical Eye Closure (VEC) |
5.5 |
|||
Eye Width at 10-15 probability (EW15 |
0.57 |
UI |
Four-lane LAN WDM optical signals are received by the receiver. By demultiplexing the optical signals through a 1-to-4 optical DEMUX, each channel of optical signals is fed into one of four receivers packaged into the Receiver Optical Sub-Assembly (ROSA). Electrical signals are converted from optical signals by receivers.
As the regenerated electrical signals are de-jittered and retimed, the RX portion of the 4-channel CDR amplifies them. Four-lane output electrical signals are retimed to meet CEI-28G-VSR interface requirements. A DOM section also monitors each optical signal that is received. Through the 2-wire serial interface, the monitored value is reported. In the event of weak optical signals, the RX_LOS hardware alarm will be triggered.
Optical Properties
Parameter |
Minimum |
Typical |
Maximum |
Lane Wavelength L0 |
1294.53 |
1295.56 |
1296.59 nm |
L1 |
1299.02 |
1300.05 |
1301.09 nm |
L2 |
1303.54 |
1304.58 |
1305.63 nm |
L3 |
1308.09 |
1309.14 |
1310.19 nm |
Transmitter |
|||
SMSR |
30 |
dBm |
|
Total Average Launch Power |
10.5 dBm |
||
Average Launch Power/lane |
-2.9 |
4.5 dBm |
|
OMA |
0.1 |
4.5 dBm |
|
Difference in Launch Power |
3.6 dBm |
||
Launch Power OMA |
-0.65 |
dBm |
|
TDP, each Lane |
2.5 dBm |
||
Eye Mask coordinates: X1, X2, X3, Y1, Y2, Y3 |
{0.25, 0.4, 0.45, 0.25, 0.28, 0.4} |
||
Extinction Ratio |
7 |
dB |
|
Receiver |
|||
Damage Threshold, each Lane |
-3.0 |
dBm |
|
Total Average Receive |
10.5 dBm |
||
Average Launch Power/lane |
-16.9 |
4.9 dBm ( 30 Km ) |
|
Average Launch Power/lane |
-20.9 |
4.9 dBm ( 40 Km ) |
|
Receive Power (OMA) |
-1.9 dBm |
||
Receiver Sensitivity (OMA) |
-14.65 dBm |
||
Stressed Receiver Sensitivity (OMA), |
-12.65 dBm |
PIN DESCRIPTION:-
Pin |
Logic |
Symbol |
Name |
1 |
GND |
Module Ground |
|
2 |
CML-I |
Tx2- |
Transmitter inverted data input |
3 |
CML-I |
Tx2+ |
Transmitter non-inverted data input |
4 |
GND |
Module Ground |
|
5 |
CML-I |
Tx4- |
Transmitter inverted data input |
6 |
CML-I |
Tx4+ |
Transmitter non-inverted data input |
7 |
GND |
Module Ground |
|
8 |
LVTTL-I |
MODSEIL |
Module Select |
9 |
LVTTL-I |
ResetL |
Module Reset |
10 |
VCCRx |
+3.3v Receiver Power Supply |
|
11 |
LVCMOS-I |
SCL 2 |
wire Serial interface clock |
12 |
LVCMOS-I/O |
SDA 2 |
wire Serial interface data |
13 |
GND |
Module Ground |
|
14 |
CML-O |
RX3+ |
Receiver non-inverted data output |
15 |
CML-O |
RX3- |
Receiver inverted data output |
16 |
GND |
Module Ground |
|
17 |
CML-O |
RX1+ |
Receiver non-inverted data output |
18 |
CML-O |
RX1- |
Receiver inverted data output |
19 |
GND |
Module Ground |
|
20 |
GND |
Module Ground |
|
21 |
CML-O |
RX2- |
Receiver inverted data output |
22 |
CML-O |
RX2+ |
Receiver non-inverted data output |
23 |
GND |
Module Ground |
|
24 |
CML-O |
RX4- |
Receiver inverted data output |
25 |
CML-O |
RX4+ |
Receiver non-inverted data output |
26 |
GND |
Module Ground |
|
27 |
LVTTL-O |
ModPrsL |
Module Present, internal pulled down to GND |
28 |
LVTTL-O |
IntL |
Interrupt output, should be pulled up on host board |
29 |
VCCTx |
+3.3v Transmitter Power Supply |
|
30 |
VCC1 |
+3.3v Power Supply |
|
31 |
LVTTL-I |
LPMode |
Low Power Mode |
32 |
GND |
Module Ground |
|
33 |
CML-I |
Tx3+ |
Transmitter non-inverted data input |
34 |
CML-I |
Tx3- |
Transmitter inverted data input |
35 |
GND |
Module Ground |
|
36 |
CML-I |
Tx1+ |
Transmitter non-inverted data input |
37 |
CML-I |
Tx1- |
Transmitter inverted data input |
38 |
GND |
Module Ground |
PIN OUT DETAIL:
MECHANICAL FEATURES:-
Ordering Info:
Model |
Description |
QSFP28-ER4-100G |
QSFP28 100GBASE-ER4 1310nm 40km Transceiver |
For More Information:
For more information about switches & other accessories, visit blog pages or make contact with the technical support team
Warranty Information:-
For warranty information, visit https://syrotech.com/warranty-disclaimer/.
100g transceiver delivers exceptional performance over a 40km range, making it an excellent choice for long-distance connections.
Syrotech qsfp28 100g er4 transceiver module seamlessly integrates into existing setups. Great results without any complications!
The full-duplex capability of the syrotech qsfp-100g-er4 ensures seamless communication.